• Industries
    • Food
    • Logistik
    • Online trading
    • Supermarkets
  • Services
    • Planning & Engineering
    • NH3 systems
    • CO2 systems
    • Heat pump integration
    • Chillers
    • Optimization of existing systems
  • Knowledge
    • FAQ
    • Subsidies
    • Energy Efficiency Act (EnEfG) Calculator
  • About Us
    • Our Team
  • Contact us
  • German

Contact us

+49 30 549092285

engineering@cold.world

Follow us

Instagram Facebook LinkedIn
cold.world engineering
  • Industries
    • Food
    • Logistik
    • Online trading
    • Supermarkets
  • Services
    • Planning & Engineering
    • NH3 systems
    • CO2 systems
    • Heat pump integration
    • Chillers
    • Optimization of existing systems
  • Knowledge
    • FAQ
    • Subsidies
    • Energy Efficiency Act (EnEfG) Calculator
  • About Us
    • Our Team
  • Contact us
  • German

Troubleshooting on site

NH₃ refrigeration system in large warehouse back in stable operation

For one of our customers, the operator of a large warehouse with three NH₃ refrigeration systems, we were asked to assist with a fault-prone system. Our team was on site at short notice and was able to restore the system to a stable and efficient operating state through targeted analysis and technical measures.

Plant overview

The warehouse is supplied by three separate refrigeration systems:

1× single-stage NH₃ compound system for normal cooling

2× two-stage NH₃ compound systems for the deep-freeze areas

In one of the standard cooling systems, malfunctions occurred during operation, which led to high loads on the condensing unit and unstable control conditions.

On-site analysis – identified problems:

Extraneous air in the NH₃ refrigerant circuit → caused unstable pressure conditions and poor heat transfer

Defective high-pressure transmitter → supplied incorrect values to the control system

Condenser permanently under full load → high condensing pressures with a condensing temperature that is too cold at the same time

Measures implemented:

Professional venting of the refrigerant circuit

Replacement of the defective transmitter to restore reliable control

Adjustment of the control parameters to optimize the condensation performance

Before and after: comparison of control behavior

The following image shows an excerpt from the system visualization – specifically the control behaviour of the condenser fans for controlling the high pressure.

  • Blue line: High pressure curve
  • Yellow line: Fan requirement

Before our application:
Despite 100% fan demand, the pressure increased continuously. The utilization of the fans showed a restless, clocking behavior without any noticeable effect on the pressure level.

After troubleshooting:
An even, stable pressure profile with moderate fan utilization shows the success of the measures implemented. The system has been running reliably and energy-efficiently ever since.

Result:

Stable operation of the affected cooling system

Normalized condenser load and significantly reduced energy consumption

Restoration of operational safety without interfering with the other system areas

Conclusion

Our on-site support has shown how important in-depth specialist knowledge, experience with NH₃ systems and a structured analysis are in order to get existing systems back on track quickly and effectively.

Our projects

  • Operator responsibility
  • Energy optimization
  • System support
  • Operator responsibility
  • Energy optimization
  • System support

In Focus

  • Planning & Engineering
  • NH3 systems
  • CO2 systems
  • Heat pump integration
  • Chillers

Navigation

  • Imprint
  • Privacy policy
  • Contact us
  • FAQ

Folge uns

Instagram LinkedIn Youtube

Copyright © 2024 — cold.world GmbH

Designed by WPZOOM

Zustimmung verwalten
Um dir ein optimales Erlebnis zu bieten, verwenden wir Technologien wie Cookies, um Geräteinformationen zu speichern und/oder darauf zuzugreifen. Wenn du diesen Technologien zustimmst, können wir Daten wie das Surfverhalten oder eindeutige IDs auf dieser Website verarbeiten. Wenn du deine Zustimmung nicht erteilst oder zurückziehst, können bestimmte Merkmale und Funktionen beeinträchtigt werden.
Funktional Always active
Die technische Speicherung oder der Zugang ist unbedingt erforderlich für den rechtmäßigen Zweck, die Nutzung eines bestimmten Dienstes zu ermöglichen, der vom Teilnehmer oder Nutzer ausdrücklich gewünscht wird, oder für den alleinigen Zweck, die Übertragung einer Nachricht über ein elektronisches Kommunikationsnetz durchzuführen.
Vorlieben
Die technische Speicherung oder der Zugriff ist für den rechtmäßigen Zweck der Speicherung von Präferenzen erforderlich, die nicht vom Abonnenten oder Benutzer angefordert wurden.
Statistiken
Die technische Speicherung oder der Zugriff, der ausschließlich zu statistischen Zwecken erfolgt. Die technische Speicherung oder der Zugriff, der ausschließlich zu anonymen statistischen Zwecken verwendet wird. Ohne eine Vorladung, die freiwillige Zustimmung deines Internetdienstanbieters oder zusätzliche Aufzeichnungen von Dritten können die zu diesem Zweck gespeicherten oder abgerufenen Informationen allein in der Regel nicht dazu verwendet werden, dich zu identifizieren.
Marketing
Die technische Speicherung oder der Zugriff ist erforderlich, um Nutzerprofile zu erstellen, um Werbung zu versenden oder um den Nutzer auf einer Website oder über mehrere Websites hinweg zu ähnlichen Marketingzwecken zu verfolgen.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
Einstellungen ansehen
  • {title}
  • {title}
  • {title}